Mixed Center Testing

Mixed Center Testing

Petracarbon - mixed centre testing banner1

Mixed Center Testing for .050″ (1.27) Travel

Mixed Center testing for .050″ (1.27) Stroke probes, shows a typical installation of the Quad 00, SS30, SS50, SS75, and SS/GSS.

Common Factors:

  • Maximum travel is .050″ (1.27)
  • Rated travel is .050″ (1.27)
  • Except for Quad 00 and SS30 probe.
  • .100″ (2.54) Max. Travel
  • .067″ (1.70) Rated Travel

Special Considerations:

  • The SS/GSS probe can be used with other probe assemblies without any complications. When installed, the SS/GSS receptacle extends .015″ (0.38) above the mounting plate, for a total extension of .115″ (2.92) (assuming a SS/GSS probe with a .040″ (1.02) head length).
  • The plunger extension of the SS75 probe is .130″ (3.30). Since the SS/GSS receptacle can not be installed other than described above. When the SS30, SS50, and the SS/GSS are used with the SS75, the SS75 will travel .050″ (1.27), and the SS30, SS50, and SS/GSS will travel .030″ (0.76) to .035″ (0.89).

Mixed Center Testing for .250″ (6.35) Travel

Mixed Center testing for .250″ (6,35) Stroke, shows the typical installation of the S-100, S-075, S-50C, and S-50J probe assemblies.

Common Factors:

  • Probe extension from the receptacle for all assemblies is .330″ (8.38)
  • Receptacle press rings are located at .300″ (7.62)
  • Maximum travel is .250″ (6.35)Rated travel is .170″ (4.32)

Mixed Center Testing for .250″ (6.35) Travel (Wireless Fixture)

Mixed Center testing for .250″ (6.35) Stroke shows the typical installation of the 
S-100 or ICT-100, S-075 or ICT-075, and S-50C or ICT-50C probe assemblies.

Common Factors:

  • Probe extension from receptacle for all assemblies is .330″ (8.38)
  • Receptacle press rings are located at .300″ (7.62)
  • Maximum travel is .250″ (6.35)
  • Rated travel is .170″ (4.32)
  • Bottom probe maximum travel is .100″ (2.54)
  • Bottom probe rated travel is .067″ (1.70)